<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Blog Archives - DHAS</title>
	<atom:link href="https://dhas.com.lb/category/blog/feed/" rel="self" type="application/rss+xml" />
	<link>https://dhas.com.lb/category/blog/</link>
	<description>Dantziguian Hrayr Automation Systems sarl</description>
	<lastBuildDate>Wed, 03 Sep 2025 09:38:15 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://dhas.com.lb/wp-content/uploads/2022/06/fav2-150x150.png</url>
	<title>Blog Archives - DHAS</title>
	<link>https://dhas.com.lb/category/blog/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Revolutionizing Warehouse Fire Safety with Siemens ASD+ &#124; DHAS</title>
		<link>https://dhas.com.lb/warehouse-fire-safety-siemens-asd/</link>
		
		<dc:creator><![CDATA[Lea Saad]]></dc:creator>
		<pubDate>Wed, 03 Sep 2025 09:36:08 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<guid isPermaLink="false">https://dhas.com.lb/?p=8338</guid>

					<description><![CDATA[<p>Welcome to DHAS – Pioneers in Safety &#38; Security At DHAS – Dantziguian Hrayr Automation Systems, we’re committed to equipping modern warehouses with cutting-edge solutions that ensure fire safety, reliability, and efficiency. Warehouses face unique challenges in fire detection, which is why we are spotlighting a breakthrough innovation: Siemens ASD+ – the new standard in&#8230;</p>
<p>The post <a href="https://dhas.com.lb/warehouse-fire-safety-siemens-asd/">Revolutionizing Warehouse Fire Safety with Siemens ASD+ | DHAS</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 data-start="118" data-end="169"><strong data-start="118" data-end="169">Welcome to DHAS – Pioneers in Safety &amp; Security</strong></h2>
<p data-start="171" data-end="208">At <strong data-start="375" data-end="422">DHAS – Dantziguian Hrayr Automation Systems</strong>, we’re committed to equipping modern warehouses with cutting-edge solutions that ensure <strong data-start="511" data-end="555">fire safety, reliability, and efficiency</strong>. Warehouses face unique challenges in <strong data-start="594" data-end="612">fire detection</strong>, which is why we are spotlighting a breakthrough innovation: <strong data-start="674" data-end="734">Siemens ASD+ – the new standard in warehouse fire safety</strong>.</p>
<h4 data-start="210" data-end="266">Why Traditional Detectors Fall Short in Warehouses</h4>
<p data-start="268" data-end="305"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out">Warehouses come with unique fire detection challenges:</span></p>
<ul data-start="306" data-end="463">
<li data-start="306" data-end="345">
<p data-start="308" data-end="345"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="39" data-is-only-node="">High ceilings and large open spaces</strong> lead to smoke stratification—smoke may cool and remain below ceiling-level detectors, delaying alarms.</span></p>
</li>
<li data-start="346" data-end="385">
<p data-start="348" data-end="385"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="18" data-is-only-node="">Beam detectors</strong> may suffer false alarms due to physical obstructions or misalignment.</span></p>
</li>
<li data-start="386" data-end="463">
<p data-start="388" data-end="463"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out">Traditional <strong data-start="12" data-end="31">point detectors</strong> simply aren’t sensitive enough or struggle in such vast, variable conditions.</span></p>
</li>
</ul>
<h4 data-start="465" data-end="515">Enter Siemens ASD+: A Game-Changing Solution</h4>
<p data-start="517" data-end="554"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out">Siemens’ latest innovation, the <strong data-start="32" data-end="47">ASD+ system</strong>, features two new models—<strong data-start="73" data-end="83">FDA261</strong> and <strong data-start="88" data-end="98">FDA262</strong>—engineered to overcome these exact challenges:</span></p>
<ul data-start="556" data-end="1301">
<li data-start="556" data-end="635">
<p data-start="558" data-end="635"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="22" data-is-only-node="">Unmatched Coverage</strong>: One ASD+ unit covers <strong data-start="45" data-end="63">up to 6,700 m²</strong>, the largest area available in the market. Even in ultra-sensitive Class A setups, coverage reaches <strong data-start="164" data-end="187">2,000 m² per device</strong>.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://m.digitalisationworld.com/news/69181/launch-of-asd-from-siemens-enables-largest-fire-safety-coverage?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">sid.siemens.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">m.digitalisationworld.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire Protection</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span></span></a></span></span></p>
</li>
<li data-start="639" data-end="720">
<p data-start="641" data-end="720"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="25" data-is-only-node="">Ultra-Early Detection</strong>: The active air-sampling approach ensures smoke is detected before it accumulates, bypassing issues like stratification and dilution.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://ifpmag.com/warehouse-protection-with-siemens-asd/?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">Siemens</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+4</span></span><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire Protection</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+4</span></span><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">Wikipedia</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+4</span></span></span></a></span></span></p>
</li>
<li data-start="722" data-end="803">
<p data-start="724" data-end="803"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="32" data-is-only-node="">Modular Design &amp; Lower Costs</strong>: With a modular architecture, only the aspirator or detection chamber needs replacing, extending lifetime and reducing waste.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://m.digitalisationworld.com/news/69181/launch-of-asd-from-siemens-enables-largest-fire-safety-coverage?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">Siemens</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+7</span></span><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">m.digitalisationworld.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+7</span></span><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire Protection</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+7</span></span></span></a></span></span></p>
</li>
<li data-start="805" data-end="886">
<p data-start="807" data-end="886"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="29" data-is-only-node="">Streamlined Commissioning</strong>: The <strong data-start="35" data-end="55">ASD+ Connect app</strong> uses QR codes for fast, digital commissioning—cutting setup time by up to 20%.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://m.digitalisationworld.com/news/69181/launch-of-asd-from-siemens-enables-largest-fire-safety-coverage?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">sid.siemens.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+5</span></span><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">m.digitalisationworld.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+5</span></span><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire &amp; Safety Journal</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+5</span></span></span></a></span></span></p>
</li>
<li data-start="888" data-end="969">
<p data-start="890" data-end="969"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="46" data-is-only-node="">Reliable Performance in Harsh Environments</strong>: Enhanced optics and smart signal processing distinguish between smoke and dust, dramatically reducing false alarms.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://m.digitalisationworld.com/news/69181/launch-of-asd-from-siemens-enables-largest-fire-safety-coverage?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire &amp; Safety Journal</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">m.digitalisationworld.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire Protection</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span></span></a></span></span></p>
</li>
<li data-start="971" data-end="1052">
<p data-start="973" data-end="1052"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="26" data-is-only-node="">Simplified Maintenance</strong>: Detectors can be installed in easily accessible areas rather than high ceilings, and cloud-based monitoring delivers insights—pre-alarm, dust levels, airflow, and more—directly via mobile app.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://m.digitalisationworld.com/news/69181/launch-of-asd-from-siemens-enables-largest-fire-safety-coverage?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">m.digitalisationworld.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+2</span></span><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire Protection</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+2</span></span></span></a></span></span></p>
</li>
<li data-start="1054" data-end="1135">
<p data-start="1056" data-end="1135"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="24" data-is-only-node="">Seamless Integration</strong>: ASD+ systems plug seamlessly into existing <strong data-start="69" data-end="91">Siemens Fdnet/Cnet</strong> loops—no extra hardware needed. Integrated relays allow smooth connectivity with third-party systems too.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://ifpmag.com/warehouse-protection-with-siemens-asd/?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">bombaychamber.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire Protection</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">m.digitalisationworld.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+3</span></span></span></a></span></span></p>
</li>
<li data-start="1137" data-end="1218">
<p data-start="1139" data-end="1218"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="29" data-is-only-node="">Future-Proof and Flexible</strong>: With adjustable alarm thresholds and extension slots, ASD+ adapts easily to evolving requirements.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://m.digitalisationworld.com/news/69181/launch-of-asd-from-siemens-enables-largest-fire-safety-coverage?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">facebook.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+4</span></span><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">m.digitalisationworld.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+4</span></span><span class="flex h-4 w-full items-center justify-between absolute"><span class="max-w-full grow truncate overflow-hidden text-center">International Fire &amp; Safety Journal</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+4</span></span></span></a></span></span></p>
</li>
<li data-start="1220" data-end="1301">
<p data-start="1222" data-end="1301"><span class="relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out"><strong data-start="0" data-end="30" data-is-only-node="">Planning Support Resources</strong>: Siemens supports your design process with application guides, BIM/CAD tools, spec writers, and more.</span> <span class="" data-state="closed"><span class="ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]" data-testid="webpage-citation-pill"><a class="flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]! transition-colors duration-150 ease-in-out" href="https://m.digitalisationworld.com/news/69181/launch-of-asd-from-siemens-enables-largest-fire-safety-coverage?utm_source=chatgpt.com" target="_blank" rel="noopener"><span class="relative start-0 bottom-0 flex h-full w-full items-center"><span class="flex h-4 w-full items-center justify-between"><span class="max-w-full grow truncate overflow-hidden text-center">m.digitalisationworld.com</span><span class="-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]">+1</span></span></span></a></span></span></p>
</li>
</ul>
<hr data-start="1303" data-end="1306" />
<h4 data-start="1308" data-end="1365">Why Choose ASD+ for Warehouses &amp; Logistics Centers?</h4>
<div class="_tableContainer_1rjym_1">
<div class="_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1367" data-end="1894">
<thead data-start="1367" data-end="1417">
<tr data-start="1367" data-end="1417">
<th data-start="1367" data-end="1396" data-col-size="sm">Benefit</th>
<th data-start="1396" data-end="1417" data-col-size="md">Value Proposition</th>
</tr>
</thead>
<tbody data-start="1468" data-end="1894">
<tr data-start="1468" data-end="1544">
<td data-start="1468" data-end="1497" data-col-size="sm"><strong data-start="1470" data-end="1496">Comprehensive Coverage</strong></td>
<td data-start="1497" data-end="1544" data-col-size="md">Fewer units needed, lower system complexity</td>
</tr>
<tr data-start="1545" data-end="1629">
<td data-start="1545" data-end="1578" data-col-size="sm"><strong data-start="1547" data-end="1577">Early &amp; Reliable Detection</strong></td>
<td data-start="1578" data-end="1629" data-col-size="md">Rapid response even in challenging environments</td>
</tr>
<tr data-start="1630" data-end="1715">
<td data-start="1630" data-end="1664" data-col-size="sm"><strong data-start="1632" data-end="1663">Cost &amp; Sustainability Savvy</strong></td>
<td data-start="1664" data-end="1715" data-col-size="md">Less waste, quicker setup, reduced false alarms</td>
</tr>
<tr data-start="1716" data-end="1803">
<td data-start="1716" data-end="1742" data-col-size="sm"><strong data-start="1718" data-end="1741">Ease of Maintenance</strong></td>
<td data-start="1742" data-end="1803" data-col-size="md">Cloud insights and accessible hardware mean less downtime</td>
</tr>
<tr data-start="1804" data-end="1894">
<td data-start="1804" data-end="1836" data-col-size="sm"><strong data-start="1806" data-end="1835">Integration &amp; Scalability</strong></td>
<td data-start="1836" data-end="1894" data-col-size="md">Works with existing systems and adapts to future needs</td>
</tr>
</tbody>
</table>
</div>
</div>
<h4 data-start="1896" data-end="1915">Final Thoughts</h4>
<p data-start="1917" data-end="2242">For warehouses, distribution centers, and logistics facilities, where scale and safety go hand in hand, <strong data-start="2021" data-end="2128">Siemens ASD+ offers the most advanced, dependable, and cost-effective fire detection solution available</strong>. At DHAS, we&#8217;re proud to bring this innovation to you—empowering safer, smarter spaces across Lebanon and beyond.</p>
<hr data-start="2244" data-end="2247" />
<p data-start="2249" data-end="2412"><strong data-start="2249" data-end="2263">Need More?</strong> We’d be happy to assist with tailored consultations, system design, or deployment planning based on your unique site requirements. <a href="https://dhas.com.lb/contact/">Just let us know!</a></p>
<p>The post <a href="https://dhas.com.lb/warehouse-fire-safety-siemens-asd/">Revolutionizing Warehouse Fire Safety with Siemens ASD+ | DHAS</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fire Suppression System: Replacement of FM-200 by Novec 1230</title>
		<link>https://dhas.com.lb/fire-suppression-system-replacement-of-fm-200-by-novec-1230/</link>
		
		<dc:creator><![CDATA[dhasx]]></dc:creator>
		<pubDate>Tue, 02 Jan 2024 09:48:40 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<guid isPermaLink="false">https://www.dhas.com.lb/?p=7258</guid>

					<description><![CDATA[<p>What are fire suppression systems? The goal of any fire suppression system is to detect fire as soon as it starts and immediately suppress it, preventing the fire from spreading. Heat and flames are detected, a trigger signals there is a fire, and the suppression system kicks into action suppressing the fire at the source.&#8230;</p>
<p>The post <a href="https://dhas.com.lb/fire-suppression-system-replacement-of-fm-200-by-novec-1230/">Fire Suppression System: Replacement of FM-200 by Novec 1230</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>What are fire suppression systems?</h3>
<p><span style="font-weight: 400;">The goal of any fire suppression system is to detect fire as soon as it starts and immediately suppress it, preventing the fire from spreading. Heat and flames are detected, a trigger signals there is a fire, and the suppression system kicks into action suppressing the fire at the source. There are many types and sizes of fire suppression systems. The system design will vary based on the asset needing protection and the type of fire hazard. For example, a piece of </span><a href="https://www.firetrace.com/gse"><span style="font-weight: 400;">ground support equipment</span></a><span style="font-weight: 400;"> at an airport would be treated differently than a </span><a href="https://www.firetrace.com/fire-suppression-system-for-server-rooms"><span style="font-weight: 400;">server room</span></a><span style="font-weight: 400;">.</span></p>
<p>&nbsp;</p>
<h3>Types of Fire Suppression Systems</h3>
<p><span style="font-weight: 400;">There are numerous types of special hazard suppressions systems, each using a unique suppression agent. Special hazard suppression systems are </span><a href="https://resources.impactfireservices.com/special-hazard-fire-suppression-systems-a-guide-for-all-business-environments"><span style="font-weight: 400;">optimized for different business environments and certain types of fire.</span></a></p>
<p><a href="https://impactfireservices.com/products-we-service/special-hazards/"><span style="font-weight: 400;">Special hazard suppression systems</span></a><span style="font-weight: 400;"> are organized into five main categories: dry chemical, clean agent, commercial kitchen, foam, and CO2.</span></p>
<p><span style="font-weight: 400;">In this article, we going to focus on the clean agent systems and the difference between them.</span></p>
<p>&nbsp;</p>
<h3>Environmental Impact</h3>
<p><span style="font-weight: 400;">Those interested in the environmental impact of using clean agent fire suppression agents like FM-200™ and Novec™ 1230 can rest assured, knowing that both have zero ozone depletion potential (ODP).</span></p>
<p><span style="font-weight: 400;">However, they do differ when it comes to their global warming potential (GWP), or the amount of emitted greenhouse gas that is estimated to contribute to global warming each year. According to the </span><a href="https://www.nfpa.org/assets/files/AboutTheCodes/2001/2001_F2017_GFE_AAA_FD_FRStatements.pdf"><span style="font-weight: 400;">National Fire Protection Association,</span></a><span style="font-weight: 400;"> Novec™ 1230 has a GWP of 1 while FM-200™ has a GWP of 3350. This means Novec™ 1230 is the more environmentally friendly choice.</span></p>
<p>&nbsp;</p>
<h3>Comparison Table of<br />
FM-200 &amp; Novec 1230</h3>
<table>
<tbody>
<tr>
<td></td>
<td><b>3M™ Novec™ 1230</b></td>
<td><b>FM-200</b></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Type of Compound</span></td>
<td><span style="font-weight: 400;">Fluid Fluoroketone</span></td>
<td><span style="font-weight: 400;">Hydrofluorocarbon</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Appropriate for fire hazards</span></td>
<td><span style="font-weight: 400;">Class A, B and C</span></td>
<td><span style="font-weight: 400;">Class A, B and C</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Electrically non-conductive</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Discharge Time</span></td>
<td><span style="font-weight: 400;">10 seconds or less</span></td>
<td><span style="font-weight: 400;">10 seconds or less</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Storage</span></td>
<td><span style="font-weight: 400;">Stored as a liquid</span></td>
<td><span style="font-weight: 400;">Stored as a liquefied compressed gas</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Proximity of Cylinders to Protected Space</span></td>
<td><span style="font-weight: 400;">Must be located very near or within the space to be protected</span></td>
<td><span style="font-weight: 400;">Must be located very near or within the space to be protected</span></td>
</tr>
<tr>
<td colspan="3"><b>Environmental Impact:</b></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Ozone Depletion Potential (ODP)</span></td>
<td><span style="font-weight: 400;">None</span></td>
<td><span style="font-weight: 400;">None</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Atmospheric Lifetime (Years)</span></td>
<td><span style="font-weight: 400;">0.014</span></td>
<td><span style="font-weight: 400;">33-36.5</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Global Warming Potential (GWP)</span></td>
<td><span style="font-weight: 400;">1</span></td>
<td><span style="font-weight: 400;">3500</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Global Environmental Warranty on Agent (Years)</span></td>
<td><span style="font-weight: 400;">20 Years</span></td>
<td><span style="font-weight: 400;">None</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Subject to Phase-Down under EU F-Gas Regulation</span></td>
<td><span style="font-weight: 400;">No</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Subject to U.S. Proposals for Global Phase-Down under Montreal Protocol</span></td>
<td><span style="font-weight: 400;">No</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Subject to Potential U.S. EPA SNAP Status Change Proposals Directed at HFCs</span></td>
<td><span style="font-weight: 400;">No</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Manufacturer Advocating for Global HFC Phase-Down</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
</tr>
<tr>
<td colspan="3"></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Safe for humans?</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
<td><span style="font-weight: 400;">Yes</span></td>
</tr>
<tr>
<td colspan="3"><b>Potential Health Effects:</b></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Concentration</span></td>
<td><span style="font-weight: 400;">4.0-6.0%</span></td>
<td><span style="font-weight: 400;">6.7-8.7%</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">No Observable Adverse Effects Level (NOAEL)</span></td>
<td><span style="font-weight: 400;">10%</span></td>
<td><span style="font-weight: 400;">9%</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Clean Up</span></td>
<td><span style="font-weight: 400;">None</span></td>
<td><span style="font-weight: 400;">None</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Cost</span></td>
<td><span style="font-weight: 400;">Varies based on a number of factors; Typically higher in price than other systems</span></td>
<td><span style="font-weight: 400;">Varies based on a number of factors; Typically less expensive than Novec 1230 and requires less agent to protect a larger area</span></td>
</tr>
<tr>
<td><span style="font-weight: 400;">Systems are typically used in areas such as</span></td>
<td><span style="font-weight: 400;">Server rooms, healthcare facilities, libraries/record rooms, archives and museums, marine applications, any place with assets that could be ruined by water</span></td>
<td><span style="font-weight: 400;">Server rooms, healthcare facilities, libraries/record rooms, museums, military applications, any place with assets that could be ruined by water</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>FM-200 Phase down</h3>
<p><span style="font-weight: 400;">As per the AIM Act, enacted by US Congress in late 2020 as part of the Consolidation Appropriations Act, </span><b>FM-200 (HFC-227ea) is being phased down</b><span style="font-weight: 400;"> for environmental reasons </span><b>since January 1</b><b>st</b><b> 2022</b><span style="font-weight: 400;">.</span></p>
<p><span style="font-weight: 400;">Our partner (Siemens) has stopped supplying FM-200 solutions and has been providing the new alternative solution NOVEC1230 instead of FM-200.</span></p>
<p><span style="font-weight: 400;">This extinguishing agent has exactly the same extinguishing performance but a much better environmental footprint.</span></p>
<p><span style="font-weight: 400;">It is the latest generation of the chemical extinguishing agents.</span></p>
<p><span style="font-weight: 400;">Kindly be advised of the internal Siemens communication related to the matter. (<a href="https://dhas.com.lb/wp-content/uploads/2022/07/Flash_Alert_FA-01-22_Sinorix227_UL-Sales-Stop.pdf">Download PDF</a>)</span></p>
<p>&nbsp;</p>
<h3>Financial Impact:</h3>
<p><span style="font-weight: 400;">Our research indicates that not only using FM-200 is harmful to the environment; the operational costs of FM-200 will also drastically increase as the consumables will be less available in the near future.</span></p>
<p><span style="font-weight: 400;">For example, some manufacturers have already shown increases of 500% on their pricelists for FM-200 systems starting January 2022 and expect it to reach 800%</span></p>
<p>&nbsp;</p>
<h3>The technical reason of this act is:</h3>
<p><span style="font-weight: 400;">While HFCs indeed did not possess the ozone-depleting qualities of CFCs, they have come to be considered as potent greenhouse gases with high global warming potential.</span></p>
<p><span style="font-weight: 400;">HFCs was responsible for almost 20% of the man-made global warming.</span></p>
<p><span style="font-weight: 400;">To control production during this phasedown, the EPA will issue “allowances” to those organizations that a) produce or import HFCs and/or b) that use HFCs in one of the six approved applications:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">As a propellant in metered dose inhalers</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Defense spray propellant</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Manufacturing preformed polyurethane foam for marine use and trailer use</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">For etching semiconductor material or wafers</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Mission-critical military end uses, such as armored vehicle engine and shipboard fire suppression systems</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">On board aerospace fire suppression</span></li>
</ul>
<p>&nbsp;</p>
<h3>FACT SHEET</h3>
<p><span style="font-weight: 400;">THE KIGALI AMENDMENT TO THE MONTREAL PROTOCOL: HFC PHASE-DOWN</span></p>
<ul>
<li><a href="https://www.unep.org/ozonaction/resources/factsheet/kigali-amendment-montreal-protocol-hfc-phase-down" target="_blank" rel="noopener"><i><span style="font-weight: 400;">https://www.unep.org/ozonaction/resources/factsheet/kigali-amendment-montreal-protocol-hfc-phase-down</span></i></a></li>
</ul>
<p>&nbsp;</p>
<h3>References</h3>
<ul>
<li><a href="https://www.firetrace.com/" target="_blank" rel="noopener"><span style="font-weight: 400;">https://www.firetrace.com/</span></a></li>
<li><a href="https://www.controlfiresystems.com/"><span style="font-weight: 400;">https://www.controlfiresystems.com/</span></a></li>
<li><a href="https://www.suppressionsystems.com/american-innovation-and-manufacturing-act-aim-act/" target="_blank" rel="noopener"><i><span style="font-weight: 400;">https://www.suppressionsystems.com/american-innovation-and-manufacturing-act-aim-act/</span></i></a></li>
<li><a href="https://www.orrprotection.com/fm-200-resources#:~:text=Late%20in%202020%2C%20a%20new,clean%20agent%20gasses%20and%20refrigerants" target="_blank" rel="noopener"><i><span style="font-weight: 400;">https://www.orrprotection.com/fm-200-resources#:~:text=Late%20in%202020%2C%20a%20new,clean%20agent%20gasses%20and%20refrigerants</span></i></a><i><span style="font-weight: 400;">.</span></i></li>
<li><a href="https://www.statx.com/whitepaper/what-does-the-aim-act-mean-for-fire-suppression/" target="_blank" rel="noopener"><i><span style="font-weight: 400;">https://www.statx.com/whitepaper/what-does-the-aim-act-mean-for-fire-suppression/</span></i></a></li>
</ul>
<p>The post <a href="https://dhas.com.lb/fire-suppression-system-replacement-of-fm-200-by-novec-1230/">Fire Suppression System: Replacement of FM-200 by Novec 1230</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Surge Protection</title>
		<link>https://dhas.com.lb/surge-protection-systems/</link>
		
		<dc:creator><![CDATA[dhasx]]></dc:creator>
		<pubDate>Tue, 02 Jan 2024 08:08:44 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<guid isPermaLink="false">https://www.dhas.com.lb/?p=6036</guid>

					<description><![CDATA[<p>What is Surge Protection? A surge protection is an appliance designed to protect electrical devices from voltage spikes. It is also known as Surge arrester. &#160; Why do we need to protect the surge with fuses? The 3 phases lines and the neutral are wired directly to the load which is your UPS, while the&#8230;</p>
<p>The post <a href="https://dhas.com.lb/surge-protection-systems/">Surge Protection</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>What is Surge Protection?</h3>
<p>A surge protection is an appliance designed to protect electrical devices from voltage spikes. It is also known as Surge arrester.</p>
<p>&nbsp;</p>
<h3>Why do we need to protect the surge with fuses?</h3>
<p>The 3 phases lines and the neutral are wired directly to the load which is your UPS, while the surge protection is wired, as seen, parallel with respect to the load, towards the earth. That is, the 3 phase current passes directly to the load, not through the surge protection. Hence, the surge arrester or protector is then an open circuit from the earth …</p>
<p>If an electric surge (from lightning or from industrial switching) is passing to the load, on either one or on all the 3 phases lines and/or the neutral, the surge protection will react very quickly (less than 5 nanoseconds, a figure to compare with other surge protections, as seen in the data sheet “Novaris SDD3”) and will connect the relative line(s) and/or the neutral to the earth. By that, it will become normally closed to earth, thus discharging the electric surge to earth.</p>
<p>If the surge is less than 100 kAmps, the surge arrester will go back to its normal position of open circuit within 2 seconds. By that, if you had used the surge arrester for protecting your home, the lights will switch off however will be back within 2 seconds… confirming the surge arrester has performed correctly. The process occurs by cutting the inlet power for 2 seconds, grounding the lines and/or neutral to earth and getting back to normal …</p>
<p>In figure 2, the circuit breaker will isolate the load and the destroyed surge protection, thus blocking a second electric surge to pass by and destroy your UPS.</p>
<p>At some situations where the load ought to remain alive but the surge could not be replaced immediately … say at the TV/radio relay stations at the top of the mountains where there are no technicians at night. From statistics, they know that up to say 5 electric surges might pass by in one night … maybe 7 sets of surge protectors with relative fuses are installed in parallel. If one set is destroyed, the load will remain powered and still protected through 6 other sets of surge protectors with relative fuses.</p>
<p>Based on the situation of your project, you ought to decide to use fuses in parallel to isolate your UPS in case the surge protection is destroyed … or install the surge arrester behind a 3 x 50 Amps circuit breaker in series with your UPS.</p>
<p>&nbsp;</p>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-6045" src="https://dhas.com.lb/wp-content/uploads/2022/06/Figures-1-and-2-e1656490458420.png" alt="" width="923" height="648" srcset="https://dhas.com.lb/wp-content/uploads/2022/06/Figures-1-and-2-e1656490458420.png 923w, https://dhas.com.lb/wp-content/uploads/2022/06/Figures-1-and-2-e1656490458420-300x211.png 300w, https://dhas.com.lb/wp-content/uploads/2022/06/Figures-1-and-2-e1656490458420-768x539.png 768w" sizes="(max-width: 923px) 100vw, 923px" /></p>
<p>&nbsp;</p>
<p><img decoding="async" class="alignnone size-full wp-image-6046" src="https://dhas.com.lb/wp-content/uploads/2022/06/novaris.png" alt="" width="707" height="895" srcset="https://dhas.com.lb/wp-content/uploads/2022/06/novaris.png 707w, https://dhas.com.lb/wp-content/uploads/2022/06/novaris-237x300.png 237w" sizes="(max-width: 707px) 100vw, 707px" /></p>
<p>&nbsp;</p>
<h3>A Surge Protection is like a neon lamp</h3>
<p>It will protect electric surges of 10 kAmps for up to 10 times and then get destroyed with the 11<sup>th</sup> electric surge. When as well, it will get destroyed with a single electric surge of above 100 kAmps.</p>
<p>&nbsp;</p>
<h3>What happens when a Surge Protection gets destroyed?</h3>
<p>When the surge protection is destroyed, it is in a closed circuit to earth which is when the fuses installed in series with the surge protection are required, then the normal electricity of the premises will flow through the surge protection to earth. Hence, the surge protection will heat up soon and start burning from the normal electricity flowing through it to earth and set fire to the surrounding. Unless the fuses blow out to isolate the surge protection from the normal electricity lines … thus preventing the surge protection to burn and set fire around it!</p>
<p>But then if a second lower intensity electric surge arrives, it will destroy the load, that is your UPS and that is because the fuses had already blown out as the surge protection was destroyed from the earlier higher intensity electric surge!</p>
<p>&nbsp;</p>
<h2>In Conclusion</h2>
<p>Evidently, the alarm output will trigger as soon as the surge protection is destroyed to alert the personnel of the premises. So, it is better to have an independent power source rather than the mains 220 vac. And it is also suggested to combine it to a fire alarm panel.<br />
DHAS team also installs fire alarms as Solution Partners Of Siemens since above 3 decades.</p>
<p>The post <a href="https://dhas.com.lb/surge-protection-systems/">Surge Protection</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Danger of Lightning Strikes on Solar Systems</title>
		<link>https://dhas.com.lb/danger-of-lightning-strikes-on-solar-systems/</link>
		
		<dc:creator><![CDATA[Hera Kitabjian]]></dc:creator>
		<pubDate>Thu, 29 Sep 2022 12:03:45 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<guid isPermaLink="false">https://www.dhas.com.lb/?p=7787</guid>

					<description><![CDATA[<p>Danger of Lightning: Lightning is considered as one of the worst phenomena that would hit your electrical system. It can cause critical damages such as human injuries, fires and mechanical mal-function. In Lebanon the number of lightning strikes reaches 1.3 events/km2/year, leading to a total estimation of more than 13’000 strikes per year. This is&#8230;</p>
<p>The post <a href="https://dhas.com.lb/danger-of-lightning-strikes-on-solar-systems/">Danger of Lightning Strikes on Solar Systems</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="7787" class="elementor elementor-7787" data-elementor-post-type="post">
						<section class="elementor-section elementor-top-section elementor-element elementor-element-5ee6dfda elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="5ee6dfda" data-element_type="section" data-e-type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5d60f417" data-id="5d60f417" data-element_type="column" data-e-type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
						<div class="elementor-element elementor-element-63897bee elementor-widget elementor-widget-text-editor" data-id="63897bee" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p></p>
<h3>Danger of Lightning:</h3>
<p>Lightning is considered as one of the worst phenomena that would hit your electrical system.<br><span style="color: var(--the7-base-color); letter-spacing: var(--the7-base-letter-spacing); text-transform: var(--the7-base-text-transform); word-spacing: normal;">It can cause critical damages such as human injuries, fires and mechanical mal-function.</span></p><p>In Lebanon the number of lightning strikes reaches 1.3 events/km<sup>2</sup>/year, leading to a total estimation of more than 13’000 strikes per year.</p>
<p>This is a high risk for solar systems.<br>That is why many international standards (such as IEC 60364-7-712) are established in close collaboration with the International Organization for Standardization (ISO) to ensure safety measures are taken when installing solar power supply systems.</p>
<h3>Do Lightning Damage Solar System?</h3>
<p>Renewable energy systems are invading the power generation sector; knowing the high cost invested in solar systems, it is clear that protection against natural hazards is a must for electronics installed on a rooftop.<br>Statistically, lightning is a main cause for the damage in solar systems (32%).<br>This results in high maintenance expense when no adequate protection is implemented.</p>
<p>One might wonder how this could happen:</p>
<p>The lightning risk is divided in two parts:</p>
<ul>
<li>Direct Strike</li>
<li>Indirect strike (also called surge)</li>
</ul>
<p>The direct lightning strike is sporadic but severe: it is caused by an electrical discharge caused by&nbsp;imbalances between storm clouds and the ground, or within the clouds themselves; and can render your system useless. Panels can melt, inverters and other components can be damaged permanently due to the inductive effect.</p>
<p>The indirect lightning, or surge, is divided into two parts:</p>
<ul>
<li>The first is ground current caused by lightning striking an object nearby (tree, metallic structure…) and consequent electricity travelling through ground to reach the system</li>
<li>The second is side flash which occurs when a lightning hits an object and jumps to another object.</li>
</ul>
<h3>Why DHAS?</h3>
<p><span style="color: var(--the7-base-color); letter-spacing: var(--the7-base-letter-spacing); text-transform: var(--the7-base-text-transform); word-spacing: normal;">Installing solar panels near a thunderstorm is risk-free only w</span>hen a trustworthy expert installs the system using high-quality materials.<br>All that is required is to ensure that the company does a reliable job and considers adequate lightning protection to ensure your solar panel is well preserved.</p>
<p>DHAS specialized team provides the most effective and modern ways for lightning protection, based on years of researches and experience (since 1973) while following international standards.</p>
<p>DHAS engineering team provides full protection solutions for solar systems including grounding and surge arrestors.</p>
<p>Professionals frequently advise grounding as a practical way to safeguard your solar system. By using this technique, lightning is diverted. You cannot stop lightning from striking, but you may deflect it away from solar panels and toward the earth, which is a helpful rule of thumb. Grounding also requires proper measurement to assure functionality. DHAS provides the right tools to guarantee the low resistance of the grounding.</p>
<p>Solar panels are protected by surge arrestors which take up induced voltage from impacts and ground them. The quality of the surge arrestor controls its functioning, while price varies a lot based on the performance of the devices, we strongly advise a proper selection of such device for your system.</p>
<h1><img decoding="async" src="https://dhas.com.lb/wp-content/uploads/2022/09/chart-300x82.png" alt="" width="651" height="178"></h1>
<h3>Conclusion</h3>
<p>Safety always comes first and risks can be minimized through preventive measures.</p>
<p>In the case of a lightning, you have the power to redirect the current away from your equipment and the chance to save them for damages.</p>								</div>
				</div>
					</div>
		</div>
					</div>
		</section>
				</div>
		<p>The post <a href="https://dhas.com.lb/danger-of-lightning-strikes-on-solar-systems/">Danger of Lightning Strikes on Solar Systems</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>EN 54-29 Standard for fire detection</title>
		<link>https://dhas.com.lb/en-54-29-standard-for-fire-detection/</link>
		
		<dc:creator><![CDATA[dhasx]]></dc:creator>
		<pubDate>Wed, 29 Jun 2022 07:59:21 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<guid isPermaLink="false">https://www.dhas.com.lb/?p=6023</guid>

					<description><![CDATA[<p>It defines the requirements for multiple sensor detectors (known as combined detectors or smoke and heat detectors) to offer more reliable and accurate early smoke detection. Siemens is one of the first companies to offer multiple sensors detectors respecting the EN 54-29.The new European standard EN 54-29 was enforced since May 2015 in Europe. So far, the&#8230;</p>
<p>The post <a href="https://dhas.com.lb/en-54-29-standard-for-fire-detection/">EN 54-29 Standard for fire detection</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>It defines the requirements for multiple sensor detectors (known as combined detectors or smoke and heat detectors) to offer more reliable and accurate early smoke detection. <a href="http://www.buildingtechnologies.siemens.com/bt/global/en/firesafety/pages/fire-safety.aspx" target="_blank" rel="noopener">Siemens</a> is one of the first companies to offer multiple sensors detectors respecting the EN 54-29.The new European standard EN 54-29 was enforced since May 2015 in Europe.</p>
<p>So far, the standards <a href="https://en.wikipedia.org/wiki/EN_54" target="_blank" rel="noopener">EN 54-5 and EN54-7</a> have been applicable for point detectors. They specify the requirements for smoke and heat detectors.</p>
<h3>Highest level of security by multiple analysis</h3>
<p>With the EN 54-29 standardization organizations are now setting new standards in fire alarm engineering. It specifies the requirements of fire detectors containing one sensor for smoke and one sensor for hear. These detectors spot imminent fires by means of an intelligent combination of algorithms of smoke and temperature parameters. Thanks to its multiple sensor system these detectors respond far more precisely as EN 54-5 and EN 54-7 – tested devices and they are also much less prone to deceptive interference than mere smoke detectors.</p>
<h3>Scope of the EN-54-29</h3>
<p>This European Standard EN 54-29 specifies requirements, test methods and performance criteria for point type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54-1:1996), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena. Multi-sensor fire detectors having special characteristics suitable for the detection of specific fire risks are not covered by this standard. The performance requirements for any additional functions are beyond the scope of this standard (e.g. additional features or enhanced functionality for which this standard does not define a test or assessment method).</p>
<h3>Siemens ASA Technology</h3>
<p>Protecting people and assets and securing business processes are of utmost importance. That’s why <a href="http://www.buildingtechnologies.siemens.com/bt/global/en/firesafety/fire-detection/cerberus-pro-fire-safety-system/Pages/cerberus-pro.aspx" target="_blank" rel="noopener">Cerberus™ PRO</a> provides the ideal fire safety solution for any application area. Detectors with the innovative <a href="http://www.downloads.siemens.com/download-center/Download.aspx?pos=download&amp;fct=getasset&amp;id1=A6V10360564" target="_blank" rel="noopener">ASAtechnology™</a> (<a href="http://w3.usa.siemens.com/buildingtechnologies/us/en/fire-products-and-systems/fire-protection-products/fire-detection/advanced-detection-innovations/Documents/Siemens%20_White_paper_ASA_Technology.pdf" target="_blank" rel="noopener">ASA = advanced signal analysis</a>) are the best choice for protecting especially demanding application areas. Because in environments like data centers and industrial<br />
production facilities, you need highly advanced technology to ensure maximum safety and optimal protection – with no false alarms.</p>
<p>&nbsp;</p>
<p><a href="https://dhas.com.lb/contact/">Contact Us</a> for more info, we would be happy to provide you with the needed info.</p>
<p>The post <a href="https://dhas.com.lb/en-54-29-standard-for-fire-detection/">EN 54-29 Standard for fire detection</a> appeared first on <a href="https://dhas.com.lb">DHAS</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
